Power Analyzers and Power Meters
Power Analyzers and Power Meters
±(0.8% rdg + 0.2% rng) when using clamps , , , , ±(1.1% rdg + 0.2% rng) when using clamp , ±(1.3% rdg + 0.2% rng) when using clamp ,
SUIN contains other products and information you need, so please check it out.
Peak voltage of 2 kV or RMS of 1.1 kV, whichever is lower
Peak voltage of 1.5 kV or RMS of 1.0 kV, whichever is lower
Peak voltage of 1.5 kV or RMS of 1.0 kV, whichever is lower
Peak voltage of 1.5 kV or RMS of 1.0 kV, whichever is lower
The peak is 1.5 kV, or the RMS of 1kV, whichever is less.
The peak is 1.6 kV, or the RMS of 1.1kV, whichever is less.
Peak voltage of 2 kV or RMS of 1.1 kV, whichever is lower
Peak voltage of 1.6 kV or RMS of 1.5 kV, whichever is lower
Continuous Allowable Max. Input Current
Direct input (5 A element): Peak current of 10 A or RMS of 7 A (whichever is lower.), Direct input (30 A element): Peak current of 90 A or RMS of 33 A (whichever is lower.) External Current Sensor Input - Peak not to exceed 5 times range-value or 25 V (whichever is lower)
Direct input (5 A element): Peak current of 10 A or RMS of 7 A (whichever is lower.), Direct input (50 A element): Peak current of 150 A or RMS of 55 A (whichever is lower.) External Current Sensor Input - Peak not to exceed 5 times range-value
30A direct input: The peak is 90 A, or RMS is 33 A, whichever is less. 2A direct input: The peak is 6 A, or RMS is 2.2 A, whichever is less. Current sensor input: The peak is not to exceed 5 times the range
Additional reading:The Benefits of Using Signal Frequency Counter Manufacturing for Improved Production Efficiency
Want more information on Three-Phase Power Quality Analyzer Manufacturer? Feel free to contact us.
Direct input: The peak is 100 A, or RMS is 45 A, whichever is less. External input: The peak is 5 times the range or less.
Direct input: 5-200 mA Peak current of 30 A or RMS of 20 A (whichever is less.), 0.5-20 A Peak current of 100 A or RMS of 30 A (whichever is less.) External input: Peak value of 5 times range or less.
Direct input: 1-20 A Peak current of 100 A or RMS of 44 A (whichever is less.) External input: Peak value of 5 times range or less.
Direct input: 0.5-20 A Peak current of 100 A or RMS of 30 A (whichever is less.) External input: Peak value of 5 times range or less.
Direct input: 8.5 A Peak or RMS of 6 A (whichever is less.) External input: Peak value of 4 times range or less.
(2A) 60Arms (50A) 130Arms (100A) 100Arms (200A) 250Arms (500A) 500Arms (A) A (A) A
Power Analyzers
Extech PQ 1-/3-Phase A True RMS AC Power Clamp Meter
Extech PQ: 1-/3-Phase A True RMS AC Power Clamp MeterMultifunction Meter with Built-In Non-Contact Voltage DetectorFeatures: Meter operates...
$350.89Add:
EXTECH PQ-1 3-Phase Power & Harmonics Analyzers
Extech PQ-1: 3-Phase Power & Harmonics AnalyzersComplete with A 12" flexible current clamp probesFeatures: Datalogging of single and...
$3,909.00Add:
EXTECH PQ-3 3-Phase Power & Harmonics Analyzers
Extech PQ-3: 3-Phase Power & Harmonics AnalyzersComplete with A 18" flexible current clamp probesFeatures: Datalogging of single and...
$4,019.00Add:
EXTECH PQ A 3-Phase Power Analyzer/Datalogger
Extech PQ: A 3-Phase Power Analyzer/DataloggerDatalogging Power Analyzer (up to 30,000 sets of measurements)Features: Large dot-matrix,...
$2,029.00Add:
EXTECH PQ-12
Extech PQ-12: A 3-Phase Power Analyzer/Datalogger KitDatalogging Power Analyzer (up to 30,000 sets of measurements)Features: Large...
If you want to learn more, please visit our website Three-Phase Power Quality Analyzer Dealer.
$2,719.00Add: